Table of Contents

Multipath

Zakladni prikazy:

Vzorova konfigurace

blacklist {
        wwid .*
}
blacklist_exceptions {
        property "(ID_WWN|SCSI_IDENT_.|ID_SERIAL)"
        wwid "26261353635663533|2317936357870636c"
}
 
defaults {
#                verbosity 6
                failback        manual
                path_grouping_policy  failover
                features "0"
                no_path_retry fail
}
multipaths {
       multipath {
              wwid              26261353635663533
              alias             backup
        }
       multipath {
              wwid              2317936357870636c
              alias             mach3
        }
}

Pridani noveho multipath zarizeni

Manual failover

1) vyradit jednu z cest

echo offline > /sys/block/ [device name] /device/state

2) cestu vratit zpet

echo running > /sys/block/ [device name] /device/state

Je to vhodne udelat po automatickem failover v pripade, ze se prepne cesta z fc na iscsi. Je nastaveno nevracet se zpet, takze zabitim aktivniho ISCSI donutime multipath zase zacit pouzivat FC