Line 1: | Line 1: | ||
+ | ====== Recommended reset/clear ======= | ||
+ | <code> | ||
+ | switchdisable | ||
+ | cfgdisable (hit "y" at prompt) | ||
+ | cfgclear (hit "y" at prompt) | ||
+ | cfgsave (hit "y" at prompt) | ||
+ | configdefault | ||
+ | switchenable | ||
+ | reboot | ||
+ | </code> | ||
+ | Recommended action as these are the 'cleanest' methods. There is a command to 'reset back to factory defaults', but have never recommended its use as some negative results have occurred. Also since we didn't know what the actual catalyst of the problem was in conjunction with the command, its just better to steer clear and use the steps given above. | ||
<code> | <code> | ||
switch:admin> ipaddrset | switch:admin> ipaddrset | ||
Line 12: | Line 23: | ||
switch:admin> | switch:admin> | ||
</code> | </code> | ||
+ | |||
+ | ======Brocade silkworm 3200 a MRTG===== | ||
+ | SNMP nastavime velmi intuitivnim prikazem ''agtcfgset'' | ||
+ | <code> | ||
+ | switch:admin> agtcfgSet | ||
+ | </code> | ||
+ | |||
+ | A na strane linuxoveho mrtg pouzijeme tento konfigurak pro jeden port: | ||
+ | <code> | ||
+ | LoadMIBs: /home/mrtg/v2_2SW.mib # this is the directory where the mib is located | ||
+ | |||
+ | Target[10.0.32.53.47]: 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.12.1&1.3.6.1.4.1.1588.2.1.1.1.6.2.1.11.1:public@10.32.53.47 * 4 | ||
+ | Title[Brocade]: fc throughput on switch brocade (uplne dole) port 00 | ||
+ | </code> | ||
+ | |||
+ | Hodnota v counteru se musi vynasobit 4, porty se cisluji od 1. MIB soubor je ke stazeni zde | ||
+ | * {{:hardware:v2_2sw.mib.gz|}} |